Cartridges are not reusable.
One micron absolute rated cartridges for
Cryptosporidium & Giardia Cysts removal.
 Poly-pleat
cartridges are designed for drinking water applications to remove
Cryptosporidium and Giardia Cysts
and when one micron absolute rated filtration is required. Absolute
rated Poly-Pleat cartridges meet or exceed the three-log (99.9%)
removal requirements for cyst reduction and are certified effective
by independent testing.
Cartridges are rated for temperatures to 140°F(60°C). Polypropylene
filter media offers compatibility with many aggressive chemicals.
Poly-Pleat cartridges are certified to ANSI-NSF61.
Independent Lab Validated
To demonstrate the performance of POLY-PLEATÔ cartridges
and HARMSCO filter housings, Analytical Services, Inc., a highly
respected independent testing facility, was selected to conduct
challenge studies using live organisms. The challenge system was
composed of a reservoir, pump, static mixer, pressure gauges and
challenge bleed–off assembly. The test protocol has been reviewed
and approved by leading states in the country and is considered
the most stringent method used for cyst reduction testing. The protocol
includes two separate spikes on two different but identical test
filters using live Giardia lamblia cysts and Cryptosporidium parvum
oocyst. An initial Giardia/Cryptosporidium spike is performed early
in the filter run to document the filter’s efficiency. After
injection of the challenge organisms, test samples are collected
in two phases during an uninterrupted 36hour run. During the first
sampling phase of 1-18hours, calibrated side-stream samples were
collected from both the influent and the effluent of the test filter.
Because no cysts are injected during the second phase, only effluent
samples are collected during the 19-36 hour test period. Results
of the 19-36 hour challenge tests are as follows:
Results
of Cryptosporidium and Giardia cysts challenge study |
| Cartridge Tested |
Filter Housing |
Tested Flow Rate |
Challenge Organisms |
Percent Removed |
| PP-D-1 |
HIF-14 Filter |
50GPM |
Giardia lamblia cysts |
99.99% |
| PP-HC-170-1 |
HUR-170-HP
Hurricane Filter |
100GPM |
Cryptosporidium parvum
oocysts Giardia lambia cysts |
99.98%
99.9% |
| Tests conducted
by Analytical Services, Inc./ Williston,VT |
Specification
| Micron ratings |
One micron absolute
for Cryptosporidium and Giardia cysts. |
| Filter media |
Meltblown polypropylene
inner layer with outer layers of polypropylene scrim material
for support |
| Center tubes |
Rigid PVC with
perforations, or molded polypropylene |
| End caps |
Pliable PVC with
sealing surface built-in |
| Temperature |
140°F (60°C)
temperature limit depending on pressure and time under load |
| Flow rates |
Up to 6 GPM per
9-3/4standard cartridge. For Hurricane and Big-Blue cartridges,
flow rates are limited by the housing used. |
| Netting |
Polypropylene
netting standard for 2-3/4 O.D. and Big-Blue cartridges. |
| Shrink wrap |
Standard for
all Poly-Pleat cartridges. |
Product Codes
| Filter Cartridge
Product code |
Type |
Length |
΄O.D. |
No./case |
| PP-S-1 |
Standard |
9-3/4 |
2-3/4 |
24 |
| PP-D-1 |
Standard |
19-1/2 |
2-3/4 |
24 |
| PP-T-1 |
Standard |
29-1/4 |
2-3/4 |
24 |
| PP-BB-10-1 |
Big Blue |
9-3/4 |
4-1/2 |
8 |
| PP-BB-20-1 |
Big Blue |
20 |
4-1/2 |
4 |
| PP-HC-40-1 |
Hurricane |
9-5/8 |
7-3/4 |
1 |
| PP-HC-90-1 |
Hurricane |
19-1/2 |
7-3/4 |
1 |
| PP-HC-170-1 |
Hurricane |
30-3/4 |
7-3/4 |
1 |
Cartridges are for